Ubicación: Global + English
Global Global Algérie Français Algeria English Angola Português Angola English Argentina Español Argentina English Australia English Austria Deutsch Austria English Azerbaijan English Azerbaijan Русский Bahrain English Bangladesh English Belgium English Belgium Français Belgium Nederlands Brazil Português Brazil English Bulgaria български Bulgaria English Cameroon English Cameroon Français Canada English Canada Français Chile Español Chile English China 中文 China 日本語 China English Colombia Español Colombia English Croatia English Czech Republic Čeština Czech Republic English Denmark English Djibouti English Ecuador Español Ecuador English Egypt English Estonia English Ethiopia English Finland Suomi Finland English France Français France English Georgia English Georgia Русский Germany Deutsch Germany English Ghana English Greece Ελληνικά Greece English Guatemala Español Guatemala English Hong Kong, China English Hong Kong, China 中文 Hungary Magyar Hungary English India English Indonesia English Iraq English Ireland English Italy Italiano Italy English Ivory Coast Français Ivory Coast English Japan 日本語 Japan English Jordan English Kazakhstan Русский Kazakhstan English Kenya English Kuwait English Kyrgyzstan Русский Kyrgyzstan English Latvia English Lithuania English Malaysia English Mauritius English Mauritius français (Maurice) Mexico Español Mexico English Moldova Română Moldova English Mongolia English Morocco English Morocco Français Mozambique Português Mozambique English Netherlands Nederlands Netherlands English New Zealand English Nigeria English Norway English Oman English Pakistan English Paraguay Español Paraguay English Peru Español Peru English Philippines English Poland Polski Poland English Portugal Português Portugal English Qatar English Republic of Korea 한국어 Republic of Korea English Romania Română Romania English Saudi Arabia English Serbia Српски Serbia English Singapore English Slovakia English Slovenia English South Africa English Spain English Spain Español Sri Lanka English Sweden English Switzerland Deutsch Switzerland Français Switzerland Italiano Switzerland English Tanzania English Thailand ไทย Thailand English Togo English Togo Français Tunisia English Tunisia Français Türkiye Türkçe Türkiye English Turkmenistan Русский Turkmenistan English Ukraine Українська Ukraine English United Arab Emirates English United Kingdom English Uruguay Español Uruguay English USA English Uzbekistan English Uzbekistan Русский Vietnam Tiếng Việt Vietnam English

SGH Imaging Image Evaluation: Non-Destructive Acoustic Analysis for Advanced Semiconductor Packaging

SGH imaging image evaluation is a professional non-destructive testing service based on Scanning Gigahertz Holography, an ultra-high-frequency acoustic microscopy technique that achieves micron-scale resolution for internal defect detection in semiconductor devices. This service supports failure analysis, process development, and reliability qualification for flip-chip packages, 3D IC stacks, TSV interposers, and hybrid-bonded wafers. This article introduces the technical principles, applicable sample types, testing items, evaluation methods, and typical applications of SGH imaging image evaluation.

SGH Imaging Image Evaluation

Technical Overview

SGH (Scanning Gigahertz Holography) is an advanced acoustic imaging technology that extends conventional scanning acoustic microscopy (C-SAM) into the gigahertz frequency range. By employing transducers operating at approximately 1 GHz, the acoustic wavelength in the water coupling medium is reduced to roughly 1.5 micrometers, allowing SGH imaging to resolve internal features and defects at the scale of a few micrometers. This level of detail is far beyond the capability of traditional 15–300 MHz acoustic microscopes, making SGH an essential tool for advanced semiconductor packaging inspection.

Unlike conventional pulse-echo C-SAM, which constructs images point by point from amplitude information alone, SGH records both the amplitude and phase of the reflected acoustic field and reconstructs the image holographically. This phase sensitivity enables the detection of weakly bonded or kissing interfaces, which are subtle bond-quality variations that produce little or no contrast in amplitude-based images. Because silicon is acoustically transparent at these frequencies, SGH is particularly powerful for imaging features located beneath the silicon die, such as micro-bump arrays, through-silicon vias (TSVs), and hybrid bond interfaces.

Key Capabilities

  • Micron-level lateral resolution, typically in the range of 1 to 3 micrometers
  • Fully non-destructive internal inspection using deionized water coupling
  • Combined amplitude and phase imaging for bond quality assessment
  • Deep penetration through silicon dies and vertically stacked structures
  • Quantitative defect mapping, sizing, and statistical analysis

Comparison with Conventional C-SAM

Conventional C-SAM systems typically operate between 15 MHz and 300 MHz, providing lateral resolution on the order of 10 to 100 micrometers, which is adequate for die-attach voids and large delamination but insufficient for fine-pitch micro-bumps or TSV structures. SGH raises the operating frequency to the gigahertz level, improving resolution by roughly an order of magnitude. The trade-off is reduced penetration through highly attenuating materials such as molding compounds, so SGH is generally optimized for imaging through silicon, while C-SAM remains preferable for thick organic packages. In practice, the two techniques are complementary and are often applied together in a comprehensive failure analysis workflow.

Testing Samples

SGH imaging image evaluation is applicable to a wide range of semiconductor and microelectronic samples, with particular strength in advanced packages containing fine-pitch interconnects and stacked silicon.

Package-Level Samples

  • Flip-chip packages with C4 bumps or fine-pitch micro-bumps
  • 2.5D and 3D IC packages with stacked dies and silicon interposers
  • Wafer-level chip scale packages (WLCSP) and fan-out packages
  • Ball grid arrays (BGA), chip-scale packages (CSP), and system-in-package (SiP) modules
  • MEMS devices, capped sensors, and hermetically sealed components
  • Power modules requiring die-attach and solder-layer inspection

Wafer-Level Samples

  • TSV wafers, including copper via fill quality and void detection
  • Hybrid-bonded and fusion-bonded wafer pairs, including Cu-Cu, Si-Si, and oxide bonding
  • SOI wafers and bonded wafer stacks
  • Temporary bonded and debonded carrier wafers

Testing Items

The SGH imaging image evaluation service detects, locates, and characterizes internal defects that affect yield, performance, and long-term reliability. Typical testing items include:

  • Solder bump voids and micro-voids in micro-bump arrays
  • Non-wet, open, or partially collapsed solder joints
  • Delamination at die attach, underfill, and molding compound interfaces
  • Bonding defects at hybrid bond and fusion bond interfaces, including kissing bonds
  • TSV voids, separations, and liner delamination
  • Cracks in silicon dies, interposers, and substrates
  • Particles and trapped voids at wafer-bonded interfaces
  • Depth localization of internal anomalies through gated layer-by-layer imaging

Testing Methods

Sample Preparation

Samples must have a flat, clean surface to ensure proper acoustic coupling, and they must be compatible with immersion in deionized water. Surfaces are cleaned of flux residues, contamination, and loose particles before testing. When the target interface lies deep beneath thick silicon, backside thinning may be recommended to reduce attenuation; because mechanical thinning permanently alters the sample, it is only performed with customer approval.

Scanning and Image Acquisition

The appropriate transducer frequency, typically between 300 MHz and 1 GHz, is selected based on the target feature size and depth, balancing resolution against penetration. The acoustic focus is calibrated on a reference target, and the region of interest is scanned with the gate positioned at the interface of interest. C-scan mode provides plan-view images at a selected depth, B-scan mode provides cross-sectional views for depth confirmation, and through-scan mode offers rapid screening for any gap along the acoustic path. The captured holographic data is numerically reconstructed into high-resolution amplitude and phase images.

Image Evaluation and Reporting

Acquired images are evaluated using contrast analysis, gray-scale threshold segmentation, and phase-based interface assessment to classify defects by type, size, and location. Quantitative results, such as void percentage, bump open rate, and delamination area, are calculated and compared against known-good reference units, JEDEC and IPC guidelines, or customer-specific acceptance criteria. The final deliverables include the full image set, annotated defect maps, statistical summaries, and a professional test report with conclusions and engineering recommendations.

Applications

SGH imaging image evaluation is widely used across semiconductor manufacturing, packaging development, and reliability engineering:

  • Failure analysis of electrical opens, intermittents, and thermal anomalies in advanced packages
  • Process development and optimization of bonding parameters for micro-bump, TSV, and hybrid bonding integration
  • Reliability qualification through defect comparison before and after thermal cycling, moisture exposure, and reflow stress
  • Incoming inspection and quality control of critical components
  • Research and development support for wafer-level bonding and 3D integration technologies
  • Construction analysis and counterfeit component screening

By delivering micron-scale insight into internal structures without destroying the sample, SGH imaging enables engineers to identify root causes quickly, validate process changes, and make confident qualification decisions.

FAQ

What resolution can SGH imaging achieve?

SGH imaging typically achieves lateral resolution in the range of 1 to 3 micrometers, depending on the transducer frequency and the acoustic properties of the materials involved. This is roughly ten times finer than conventional C-SAM resolution.

Is SGH imaging destructive?

No. SGH imaging is a non-destructive technique that uses pulsed ultrasound through deionized water. The sample remains electrically and mechanically functional after testing, allowing subsequent electrical verification or complementary analysis. Backside silicon thinning, when required, is an exception and is only performed with prior approval.

Can SGH image through molding compound?

Gigahertz ultrasound attenuates strongly in polymers, so thick molding compound is a challenging medium for SGH. In such cases, imaging is performed from the silicon die side, where attenuation is low. If necessary, backside grinding can expose a direct silicon path to the target interface.

How does SGH differ from X-ray inspection?

X-ray imaging distinguishes materials by density contrast and is excellent for overall solder wetting analysis, but it has limited sensitivity to thin gaps, fine cracks, and delamination. SGH is extremely sensitive to air gaps and interface quality, including kissing bonds, and therefore complements X-ray and CT methods in advanced failure analysis.

What sample sizes can be accepted?

The laboratory accepts samples ranging from individual diced components to full wafers and packaged modules. Sample dimensions and surface conditions should be confirmed with the engineering team before submission to ensure compatibility with the immersion scanning stage.

How long does a typical evaluation take?

Standard evaluation, including scanning, image reconstruction, defect analysis, and reporting, is generally completed within three to five working days. Urgent projects can be accommodated with expedited service upon request.

Why Choose ZKGX?

  • State-of-the-art analytical equipment
  • Highly qualified scientific team
  • Fast turnaround time
  • Competitive pricing